Short answer

Usually yes, once it is connected safely. A gas furnace will not operate during an outage 1: its blower and controls run on electricity 2. In a field study of 31 furnaces, standard blowers drew a median of 500 W at heating speed 2. At that load, a 2,048 Wh station lasts about 3.3 hours of nonstop blowing; the furnace cycles on and off, so real time is often longer. The catch: a furnace wired into the house needs a connection made by a licensed electrician, such as a transfer switch.

Your outage load
500W · Furnace blower≈3.3 hon 2,048 Wh
Station sizeRuntime for this load
1,024 Wh≈ 1.7 h
2,048 Wh≈ 3.3 h
2,765 Wh≈ 4.5 h
3,584 Wh≈ 5.9 h

How we calculate: capacity × 85 % usable3,4 ÷ (500 W load2 + 20 W the inverter uses on its own, our assumption: the maker does not publish it). Why these figures

Furnace on a power station

Never: run a generator indoors, in a garage or near a window, door or vent 6,7. Keep a battery-powered CO alarm on 7.

Why a gas furnace stops when the power goes out

A gas furnace will not operate during an outage, even with gas in the line 1. The burner makes the heat, but electricity runs the blower, the fan of your HVAC system that pushes warm air through the ducts, along with the controls, the igniter and the draft inducer fan. The controls alone draw 4 to 13 W on standby 2.

So the question is not whether a battery can make heat. It is whether it can run those parts long enough. Hot-water boilers have their own pump and controls: see our heating guide.

How many watts a furnace blower uses

The blower is the big load. A field study of 31 new furnaces in Wisconsin measured it 2:

  • Standard blower (PSC motor): a median of 500 W, measured in fan-only mode, where these blowers ran at their heating speed.
  • Variable-speed blower (ECM motor): a median of 100 W in fan-only mode, at low airflow. When heating, it speeds up and draws more.

A Virginia Cooperative Extension list puts a furnace fan at 750 W 9. That is a nameplate figure, a maximum rather than a typical draw.

The study dates from 2004, so your furnace may differ. Two better guides are on your side of the wall:

  1. The rating plate inside the furnace door lists the amps. Amps × 120 V gives the most it can draw.
  2. Your winter gas bill. The median standard furnace in the study used about 1 kWh of electricity per therm of gas (9.5 kWh per gigajoule); variable-speed furnaces used about half 2. If January shows 150 therms, that is 5 therms a day, or about 5 kWh of electricity a day. The bill also counts your water heater and stove, so this errs on the high side.

How long a power station will run it

The panel above assumes the blower runs nonstop at 500 W. A furnace cycles on and off, which stretches the time, while the igniter and inducer add to the draw when it fires. Treat the figures as a planning estimate, not a promise.

Station Battery AC output At 500 W nonstop
Anker SOLIX C1000 Gen 2 1,024 Wh 11 2,000 W 11 ≈ 1.7 h
EcoFlow DELTA 3 Plus 1,024 Wh 1,800 W 12 ≈ 1.7 h
BLUETTI Elite 200 V2 2,073.6 Wh 2,600 W 13 ≈ 3.5 h
BLUETTI Apex 300 2,764.8 Wh 3,840 W 14 ≈ 4.5 h
Jackery HomePower 3600 Plus 3,584 Wh 3,600 W 15 ≈ 5.9 h

Before an outage, turn off the feature that switches the outlets off on its own:

  • Anker SOLIX C1000 Gen 2: Anker’s user guide says the station’s default standby time is 12 hours and can be changed in the Anker app 11. Set the longest time, then test that the station stays on while the furnace is idle.
  • EcoFlow DELTA 3 Plus: set the AC timeout to “never” in the EcoFlow app 12.
  • BLUETTI Elite 200 V2: ECO mode is on by default, and BLUETTI says to disable it for critical appliances. Hold the AC and DC buttons for about 2 seconds to enter Settings Mode, press DC until you reach ECO Mode, then press AC; or use the BLUETTI app 13.
  • BLUETTI Apex 300: ECO mode is on by default and cuts AC output after 4 h at 10 W or less. Press the ECO button 14.
  • Jackery HomePower 3600 Plus: Energy Saving Mode is on by default and turns the outputs off after 12 h under 25 W. Hold the AC and main power buttons for more than 3 seconds 15.

How we got the runtimes: capacity × 85 % ÷ (500 W + what the station uses on its own). BLUETTI publishes that idle draw: about 10 W for the Elite 200 V2 13 and 20 W for the Apex 300 14. For the others we assume 20 W. The 85 % comes from published bench tests 3,4, and small loads can do worse 4. BLUETTI’s own formula is more cautious for the Elite 200 V2: about 3.1 h 13.

With normal on-and-off heating, divide by the average draw instead. In the gas-bill example above, 5 kWh a day is about 210 W on average: a 2,048 Wh station then lasts about 7.6 hours and a 3,584 Wh station about 13 hours.

Why switch off the energy-saving modes? Between heating cycles the furnace draws only its standby 4 to 13 W 2. A station that sees a small load for long enough may cut its outlets, and the furnace will not restart when the thermostat calls for heat.

Winter detail: the Anker, EcoFlow and both BLUETTI stations do not charge below 32 °F (0 °C) 11,12,13,14. The Jackery manual rates charging down to −4 °F (−20 °C) 15. Keep the station inside.

One more check: the Anker C1000 Gen 2 uses a floating ground, and Anker says some devices need a ground-neutral plug, sold separately 11. We could not confirm whether furnace controls are among them; ask your heating contractor.

Stock checked on 2026-11-10: the DELTA 3 Plus was on pre-order in the US, and EcoFlow Canada said it was out of stock until early next year. The Apex 300 was shipping from early December in the US. Check before you count on one.

How to connect it safely

If your furnace plugs into a wall outlet, you can plug it into the station instead. If it has no plug and is wired to a switch on or near it (the service or emergency switch), it is hard-wired. Do not improvise a connection:

  • Never plug a power source into a household outlet, and never use a cord with a plug on both ends. BC Hydro warns that a generator connected this way can feed power back into the lines and electrocute neighbours and utility workers 8; a power station can do the same.
  • Have a licensed electrician make the connection, such as a transfer switch for the furnace circuit. BC Hydro requires a properly installed, CSA-approved transfer switch to connect a generator to house wiring 8; we apply the same rule to power stations.
  • In Québec, the RBQ requires the appropriate contractor or owner-builder licence for electrical installation work 16.

A battery station gives off no exhaust, which is why it can sit inside next to the furnace. A gas generator cannot: never run it indoors, in a garage, or near a window, door or vent 5,6,7. Health Canada says to run it at least 6 metres (20 feet) from buildings 5. More in our generator carbon monoxide guide.

What else to power on the same station

Every watt-hour you give another appliance is one the furnace does not get. Two common companions:

  • The fridge. The median new full-size ENERGY STAR fridge-freezer uses about 1.3 kWh a day 17, roughly a quarter of the 5 kWh day of a standard furnace in the gas-bill example above.
  • Internet. eero lists its Wi-Fi units at 3.4 to 25 W depending on the model 18, plus your modem.

To add up your own list, use the power station calculator. For other heating types, see how to heat your house during a power outage. Our method is on the how we research page.

Questions

Will a gas furnace work without electricity?

No. A gas furnace will not operate during an outage 1: the gas makes the heat, but the blower and the controls need electricity 2. This applies to propane furnaces with a blower and electronic controls too.

How many watts does a furnace blower use?

In a field study, standard (PSC) blowers drew a median of 500 W at heating speed, and variable-speed (ECM) blowers about 100 W in fan-only mode 2. A Virginia extension list gives 750 W for a furnace fan, a nameplate figure 9. Your furnace's rating plate gives its own maximum.

How many watts does a gas furnace use per day?

In the same study, the median standard furnace used about 1 kWh of electricity per therm of gas, and variable-speed furnaces about half that 2. Multiply your daily gas use by that figure: 5 therms a day is about 5 kWh a day with a standard furnace.

What about oil and propane furnaces?

Oil furnaces use the same kinds of blower motors, standard (PSC) or high-efficiency (ECM) 10, so the blower figures above apply, plus what the oil burner draws. The rating plate gives the total. A propane furnace with a blower works like a natural gas one.

What about the starting watts of a furnace blower?

As a general rule, a motor draws about three times its running current while it starts 9. We found no figure specific to furnace blowers. Every station on this page is rated for at least 1,800 W continuous, more than three times the 500 W median.

Bottom line

A power station can keep a gas furnace heating through a short outage. With a standard blower, a 2 kWh station lasts about 3.3 hours nonstop, or about 7.6 hours of normal on-and-off heating in our gas-bill example; a 3.5 kWh station, about 5.9 and 13 hours. Have the connection made by an electrician before winter, not during the storm.

Related guides

What we checked, and what we didn't

Checked
  • Blower and furnace electricity use in a field study of 31 furnaces (ACEEE, 2004)
  • Capacity, AC output, energy-saving modes and charging temperatures in each station's manual (for Anker, only the standby time is published)
  • Stock on each brand's US and Canadian site, on 2026-11-10
  • Carbon monoxide and backfeed rules from CPSC, CDC, Health Canada and BC Hydro
Not checked
  • How your own furnace behaves on battery power. We have not tested any furnace or station.
  • Starting watts of furnace blowers, igniters and draft inducers: no reliable figure found.
  • Idle draw of the Anker, EcoFlow and Jackery stations: not published, so we assume 20 W.
  • Whether your furnace's controls work with a station's floating-ground output.

Sources

  1. Power outages (During a power outage) · FortisBC (gas and electric utility, British Columbia)
  2. Electricity Savings from Variable-Speed Furnaces in Cold Climates (field monitoring of 31 furnaces), 2004 · Pigg and Talerico, ACEEE Summer Study proceedings
  3. Jackery Explorer 1000 v2 review: measured 910 Wh of 1,070 Wh (July 23, 2026) · OutdoorGearLab
  4. The Best Portable Power Stations, Tested and Reviewed: output at 34 W and 380 W loads (updated May 5, 2025) · Outdoor Life
  5. Carbon monoxide: Preventing exposure · Health Canada
  6. Generators and Engine-Driven Tools (carbon monoxide safety guide) · U.S. Consumer Product Safety Commission
  7. What to Do to Protect Yourself During a Power Outage · U.S. Centers for Disease Control and Prevention
  8. Power during outages: generators and device chargers (Feb. 3, 2020) · BC Hydro
  9. Energy Series: Estimating Appliance and Home Electronic Energy Use (BSE-301), nameplate wattage list · Virginia Cooperative Extension
  10. Heating with Oil (2012), section on high-efficiency furnace motors · Natural Resources Canada
  11. Anker SOLIX C1000 Gen 2 user guide (US, V2, July 2025) · Anker SOLIX
  12. EcoFlow DELTA 3 Plus user manual (US) · EcoFlow
  13. BLUETTI Elite 200 V2 user manual · BLUETTI
  14. BLUETTI Apex 300 user manual (US) · BLUETTI
  15. Jackery HomePower 3600 Plus user manual · Jackery
  16. Électricité : licence (vos obligations envers la RBQ) · Régie du bâtiment du Québec
  17. ENERGY STAR Certified Residential Refrigerators dataset (queried 2026-11-10; median computed by us) · U.S. EPA ENERGY STAR
  18. How much power does eero use? · eero (Amazon)